| Physical or Performance Property |
Test Method |
Typical Value |
| Compressive Strength |
ASTM C 109 |
3 days = 44MPa(6400psi)
7 days = 51MPa(7400psi)
28 days = 60MPa(8700psi) |
| Tensile Strength |
ASTM C190 |
7 days = 6MPa(850psi) |
| Flexural Strength |
ASTM C293 |
7 days = 13MPa(1860psi)
28 days = 16MPa(2375psi) |
| Bond Strength to Concrete |
ASTM C882 |
8MPa(1200psi) |
| Water Absorption |
|
ASTM C67 1.5% |
| Abrasion Resistance |
ASTM C 807 |
20 to 25 minutes at 700F (210C) |
| Accelerated Weathering |
ASTM G23
ASTM D822 |
2,000 Hours (Carbon Arc) |
| Salt Spray Resistance |
ASTM B117 |
300 Hours - Pass |
| Freeze-Thaw Resistance |
ASTM C666 Procedure B |
200 Cycles - Pass |
| Fungus Resistance |
ASTM G21 five fungal cultures |
No Fungal Growth after
21 days |
| Water Vapour Transmission |
ASTM E96 |
Satisfactory move
ment of water vapours
at differential
pressure of 75 Pa. |
| Breathability |
ASTM E283 |
1.08L/min |
| Air Leakage |
NRC Can |
Type III Air Barrier |
| Chemical Resistance |
ASTM C267-77 “Chemical Resistance of Mortars” |
no detrimental effects on the
U-Seal when exposed to
dissolved methane gas, blood,
wine, milk, ammonia, raw
sewage, tap water. |