To ensure good, long-lasting results, apply only to clean, structurally
sound surfaces. Remove all dirt, grease, oil, efflorescence, laitance,
paint, loose mortar or anything else that may impair good bonding.
Repair all cracks or holes larger than 0.8 mm (1/32”) using
U-Plug to stop running water leaks. Use Vinyl Patch to repair dry
cracks and holes in walls and floors. If time constraints exist,
use UP 2000 to repair and patch holes and cracks in walls and floors.
In a clean mixing container place 6 litres (1 1/2 gallons) of mixing
liquid (1 part Acryli Bond to 3 parts clean potable water) and slowly
mix in powder U-Seal until a rich creamy consistency is reached.
Allow material to soak for a minimum of 5 minutes and then re-mix,
adding more mixing liquid if required. Under normal conditions each
22.7 Kg (50 lb.) bag requires 7 1/2 to 8 litres (2 gallons) of mixing
liquid. At higher temperatures more mixing liquid will be required.
Dampen previously prepared and cleaned surface immediately ahead
of application. Lay on a
heavy coat of U-Seal at a rate of 1 Kg/ m2 (2 lb./sq.yd.), using
a stiff brush or broom. Level out application of U-Seal to achieve
a uniform thickness and appearance beginning at the top of the wall
and continuing down and onto the floor. Continue to work across
the wall in this manner until application is complete. If the wall
becomes dry or the U-Seal starts to pull during application, dampen
the wall again with a fine mist of water and continue with the application
of U-Seal. Allow to dry overnight and apply a second coat to achieve
maximum waterproof protection.
Normal water conditions: Apply one coat of U-Seal at 1 Kg/m2 (2
lb/sq.yd.) and the second coat at 1/2 Kg/m2 (1lb/sq.yd.) Severe
water conditions: Apply two coats of U-Seal, both at a rate of 1
Kg/m2. (2 lb/sq.yd.)
Apply first coat of U-Seal at a rate of 1 Kg/m2 (2 lb/sq.yd.). Allow
to set and apply a trowel
coat of Stone Mason Plaster Mix at a rate of 4.9 Kg/m2 (9 lb/sq.yd.)
or sufficient material to bring surface true, level and float smooth.
Clean surface of wall to remove form release agents, dirt, dust,
efflorescence, grease, oil or loose mortar. Clean top of footer
and apply cove of mortar at intersection of wall and footing. Fill
any holes in masonry or concrete prior to applications. Apply two
brushcoats of U-Seal each at a rate of 1 Kg/m2 (2 lb/sq.yd.) ensuring
that application extends down onto the footer.
Apply a base coat of U-Seal at 1 kg/m2 (2 lbs.per sq.yd.) and allow
to cure for 5 to 7 days. Then apply a top coat of Stone Mason Plaster
Mix at 6.5 kg/m2 (12 lbs. per sq. yd.). A steel trowel finish is
recommended. For both below-grade interior and below-grade exterior
applications it is recommended to cut out and place a U-Plug cove
at the wall/floor junction prior to the application of the U-Seal
base coat.
Brush apply one coat of U-Seal at a minimum rate of 1 Kg/m2 (2 lb./sq.yd.),
ensuring that
the application extends out over the footing.
Repair all cracks or running water with U-Plug. Brush on two applications
of U-Seal each at a rate of 1 Kg/m2 (2 lb./sq.yd.).
Apply a brush coat of U-Seal at 1 Kg./m2 (2 lb./sq.yd.). Allow to
set and apply by trowel a coat of Stone Mason Plaster Mix at a rate
of 6.5 Kg./m2 (12 lb./sq.yd.) hiding all form marks and other construction
faults. Bring surface to true and even lines with sand float finish.
Remove all foreign materials from surface of pool. Repair cracks
and areas of disbonding. Brush apply two coats of U-Seal each at
a rate of 1 Kg/m2 (2 lb./sq.yd.), and float smooth before material
hardens. Water cure the finished surface with a fine mist of clean
water until the pool is to be filled. Allow 7 days curing, before
filling with water.
Repair all cracks and holes, dampen the previously cleaned surface
and apply two brush coats of U-Seal each at a rate of 1 Kg/m2 (2
lb./sq.yd.). Allow U-Seal to harden for 48 hours and then wash down
all surfaces with a brine solution (12.5% salt in water). Leave
damp brine solution on walls and floors overnight and then rinse
with clean water to remove free lime left on walls and floors. Repeat
until final rinse water is completely clean and clear.
Repair all running water leaks with U-Plug. Patch spalled areas
with UP2000 Patching Cement. Brush on two coats of U-Seal each at
a minimum rate of 1 Kg/m2 (2 lb./sq.yd.). If a smooth, true surface
is required, replace second coat of U-Seal with a trowel application
of Stone Mason Plaster Mix at a minimum rate of 6.5Kg/m2 (12 lb./sq.yd.).
Prior to placing the back-up units, apply one heavy coat of U-Seal
to the interior of the exterior wall surface. Completely fill and
seal all mortar joints, pores and voids.
Prior to placement of the coping on parapet walls, install one heavy
uniform brush coat of U-Seal at a rate of 1.5 Kg/m2 (3 lb./sq.yd.).
Be sure to cover the entire surface on the roof side from the top
of the roof flashing to the top of the wall.
Strip forms, clean wall surface, fill snap-tie holes and severe
honeycomb with UP2000 Patching Cement. Brush apply the first coat
at a minimum rate of 1 Kg/m2 (2 lb./sq.yd.). Allow to set and apply
second brush coat at the same rate as first coat. When second coat
has set, float it to a smooth uniform finish.
A 22.7 Kg (50 lb.) bag covers 22.7 m2 (225 sq.ft.) at 1 kg/m2 (2
lb./sq.yd.). For severe water conditions two coats applied at the
above rate are normally sufficient. For deep below grade applications
it may be necessary to increase amount of material applied per m2
(sq.yd.).
White / Pearl Grey
22.7 Kg / 50lb. bag
Expansion or control joints must be maintained or placed as necessary
in a structure to which U-Seal is to be applied. After the U-Seal
has cured, these joints can be filled with an appropriate caulk
or sealant. Do not apply U-Seal to frozen or frost-filled surfaces.
Do not apply when temperature is below 4°C (40°F). Do not
apply in rain. Protect fresh finish from rain. Do not use in enclosed
areas without adequate ventilation.
The consumer shall satisfy themselves of the suitability of this
product for the intended purpose. Weather, applicator’s skill
and surface conditions are beyond manufacturer’s control.
We, therefore, limit our liability to replacement of defective material
only, within one year of proof of purchase.
Corrosive. May cause eye injury. If product gets
into eyes, flush repeatedly with water and seek medical attention
promptly. Avoid skin contact. If contact occurs, wash exposed skin
with water. Protective eyewear should be worn.
AVOID CONTACT WITH EYES. FIRST AID TREATMENT: Cement
when mixed with water results in a solution of calcium hydroxide.
If splashed in eyes or skin, flush thoroughly with water.
CONTAINS: silica sands which may cause lung cancer.
|