Kop-R-Lastic should only be applied to surfaces that are free from
oil, grease, wax, dust, corrosion, moisture, or any material that
may interfere with obtaining optimum adhesion.
Fresh concrete should be fully cured and dried. This may require
as much as 3 or 4 weeks. If surfaces are dusty, they should be blown
or brushed free and cleaned. Mold release agents or curing agents
should be removed as they will prevent good adhesion. If the surface
has been exposed to oil based caulking, remove all material and
sandblast or cut surface back to remove area of oil penetration.
No primer necessary.
Unless little movement will be encountered, remove any protective
lacquer film with clean lacquer thinner. If the surface has previously
been sealed or exposed to the air for a period, remove all previous
compounds or surface oxidation via chemical treatment, solvent,
or by sandblasting, wire brushing etc. No primer is necessary.
Remove all corrosion or coatings either by chemical treatment, solvent
or by sandblasting, wire brushing etc. If chemical treatments are
necessary, rinse thoroughly. No primer necessary.
Wipe, if necessary, the surfaces to be sealed with clean, oil-free
solvent and dry thoroughly. No primer necessary.
Remove all paint, other loose coatings. Sand to provide a good,
clean surface. No primer necessary, not even on oily wood such as
teak.
KOP-R-LASTIC can be used in openings 0.32cm x 0.32 cm (1/8”x
1/8”) to approximately 1.27 cm x 1.27 cm (1/2” x 1/2”).
For good installation, when openings are greater than the desired
depth, they should be packed with a supplementary material. For
these purpose, backer rod joint filler is available and can be used.
- For neatness of joint, adjacent surfaces should be masked with
tape.
- Apply KOP-R-LASTIC in the joint from the bottom up, filling
completely and avoiding any entrapped air.
- Tool the surface for appearance and insure adequate adhesion
between the KOP-R-LASTIC and the joint sides. It is best to tool
the surface with Toluol or Xylol.
- As soon as application and tooling are completed, remove masking
tape.
Complete before KOP-R-LASTIC cures with Toluol or Xylol.
:
FLAMMABLE! Avoid sparks, open flame or any source of heat. Avoid
prolonged breathing of vapors and skin contact. Do not take internally.
Keep out of reach of children.
Keep away from heat, sparks and open flame. Avoid inhalation of
vapours and contact with skin and eyes. Keep away from food. Provide
adequate ventilation.
EYE CONTACT: Immediately flush eyes with water for 15 minutes.
SKIN CONTACT: Wash affected area thoroughly with soap and water.
INHALATION: If overcome by fumes, give patient air.
INGESTION: If swallowed, do not induce vomiting. For overexposure
seek medical attention immediately.
|